High Flow Air Humidifier Oxygen Machine

In stock

Place of Origin: China
Brand Name: Healicom
Model Number: HF7
Instrument classification: Class II
Warranty: 1 Year
Flow Range:: 2L – 80L/min
Temperature:: 29℃-37℃
O2-Air Control mode:: Software
Screen Size:: 5.0 inches
Oxygen Accuracy:: ±5%
Flow Accuracy:: ±5L/min(High flow mode:25L/min~80L/min) ±2L/min

Description

High Flow Air Humidifier Oxygen Machine

High flow heated respiratory humidifiers is mainly used to provide humidified and heated air-O2 mixed gas to the nasal cavity directly through a nasal congestion catheter without sealing, which is higher than the peak inspiratory flow rate of the patient. The oxygen concentration is accurate and adjustable, which makes the breathing more comfortable. It is an effective respiratory therapy that is suitable for invasive or non-invasive patients with spontaneous breathing, not for life support.
 
Applicable department: Respiratory medicine, ICU, Emergency room, Neurology, Neurosurgery, Cardiothoracic surgery, Pediatrics (23 kg), Rehabilitation ward, Geriatric ward, etc.
Maintain optimal humidity in combination with a nasal congestion catheter to ensure the comfortable delivery of high-flow mixed oxygen gas to achieve the following therapeutic effects: Auxiliary oxygen: Maintain a stable high inhaled gas oxygen concentration, improve oxygenation, reduce blood oxygen deficiency, and increase effective alveolar ventilation. Positive airway pressure: Produce low end-expiratory positive pressure (PEEP), reduce breathing power consumption, improve breathing frequency; promote alveolar opening, conducive to the diffusion of oxygen. Reduce dead space: Reduce the dead space of mouth, nose and pharynx, promote the conversion of oxygen and improve ventilation efficiency. Airway humidification: Gas is heated and humidified to improve mucous membrane cleaning function, promote sputum humidification and elimination, and reduce the chance of infection.

Clinical application: 1. Acute patients with mild to moderate respiratory failure in ICU or emergency room (Improve dyspnea, rise oxygenation, reduce intubation rate, and intubation mortality is significantly lower than non-invasive ventilation and standard oxygen therapy) 2. Endotracheal intubation (Improve oxygenation index, delay onset of hypoxemia) 3. Oxygen therapy after invasive withdrawal (High tolerability and comfort, reducing the rate of reintubation) 4. Acute heart failure and cardiogenic pulmonary edema (Improve dyspnea, especially refractory dyspnea) 5. Postoperative care, to mitigate the risk of respiratory failure (Replace non-invasive ventilator to achieve higher comfort) 6. Chronic airway disease (Improve the upper airway status of patients with obstructive sleep apnoea)

 
Performance Advantages
Precise oxygen concentration control and monitoring The oxygen concentration setting range is 21% to 100%. Ultra-sensitive oxygen concentration sensor and miniature proportional valve can accurately control the oxygen concentration to ensure that the mixed gas can meet any oxygen concentration requirements of patients. At the same time, the oxygen concentration can be monitored in real time to ensure that the oxygen concentration is accurate and effective.
Precise flow control and monitoring Flow setting range: 2L/min – 80L/min, the imported flow sensor can ensure the accuracy of high-flow gas, and at the same time monitor the gas flow in real time to ensure the effective treatment of patients.
Precise temperature control and monitoring Temperature control: 31℃ – 37℃, 7 levels adjustable. Applying high-sensitivity sensor and innovative intelligent dynamic control algorithm, which can accurately control the inhalation temperature of the patient end, and monitor it real-timely to ensure that the heating and humidification are safe and effective. The humidity can reach 100% to meet the needs of more patients.
Blood oxygen saturation real-time detection Optional blood oxygen module: The blood oxygen module can monitor the patient’s blood oxygen saturation and pulse rate in real time, providing more treatment information for patients and medical staff.

Dual color hypnotic lamp: Blue in normal state, and red in alarming status. Convenient to check the status of equipment from a distance Multiple alarms: As many as 12 alarms to ensure that use errors are detected in real time and keep the treatment process safe and effective History record query: It can record the temperature, flow rate and oxygen concentration for passed 1 day, 3 days, 7 days or 30 days, which is convenient to check the treatment data quickly . SD memory card: 8G large capacity memory card can store all kinds of data of patients in treatment, providing more referable detailed data for further treatment.

 
Technical Specifications
Functional items
Models
HF8
HF7
HF6
O2 control
Measurement of O2 concentration
O2 Limit alarm
Settable range
21%-100%
21%-100%
Oxygen Accuracy
±5%
±5%
O2-Air Control mode
Software
Software
Buoy flowmeter
control
Flow control function
Settable range
2-80L/min
2-70L/min
2-60L/min
Flow Accuracy
±5L/min(High flow mode: 25L/min~80L/min)
±2L/min(Low flow mode: 2L/min~25L/min)
Measurement
Temperature control function
Settable range
31℃~37℃
7 levels
31℃~37℃
7 levels
31℃~37℃
7 levels
Temperature Accuracy
±2℃
±2℃
±2℃
Measurement
Review function
History Review
Physical and Electrical
IP Classification
IP X1
Dimensions
323mmX225mmx136mm
Weight
3.2kg
Power input
AC 100-240V, 50/60Hz
Note: ● indicates with this configuration; — indicates no such configuration.
Visit our Facebook page: Tista Bangladesh

Reviews (0)

Be the first to review “High Flow Air Humidifier Oxygen Machine”

Your email address will not be published. Required fields are marked *

Reviews

There are no reviews yet.

See It Styled On Instagram

    No access token

Main Menu